Laser
Contouring System Specifications
|
Features
-
Range Uncertainty: 16 mm single shot, 6 mm averaged data;
-
Measurement speed:
8,000+ sample/s;
-
Divergence of beam:
approx. 3 mrad;
-
Field of View:
±40°
vertical, 360°
horizontal;
-
Angle step-width:
0.01°
vertical. and horizontal.
-
Angle accuracy:
0.005°
vert., 0.005°
hor.
-
Eye Safety Class:
CLASS 1
-
Max range
measurement (stand-off):
20
m
System PC
-
Pentium 4 2.8 GHz
industrial-grade touch-screen computer (or better)
-
Windows XP
operating system
-
Inclinometer
resolution — 0.6 arc-minutes (or better)
-
200°
C plenum cable throughout
-
Modular design for
simple field servicing.
Navigation System
-
Positional uncertainty: 10 mm
-
Heading
Uncertainty: 0.1°
-
Eye Safety Class:
CLASS 1
For more information on the Laser Contouring System, Contact
Michel
Bonin, Ph.D.
mbonin@processmetrix.com
Voice:
(925) 460-0385
x112
|